详细信息
Application of a novel diol-based porous organic polymer to the determination of trace-level tetracyclines in water ( SCI-EXPANDED收录 EI收录)
文献类型:期刊文献
英文题名:Application of a novel diol-based porous organic polymer to the determination of trace-level tetracyclines in water
作者:Cui, Changzheng[1];Cao, Zan[1];Zhang, Shenping[2];Hu, Yaru[1];Jiang, Lei[3];Yao, Shijie[1];Ye, Hui[3];Zhou, Yanbo[1];Hu, Jun[2];Lin, Kuangfei[1];Zhang, Tian-Yang[1]
机构:[1]East China Univ Sci & Technol, State Environm Protect Key Lab Environm Risk Asse, Sch Resources & Environm Engn, Shanghai 200237, Peoples R China;[2]East China Univ Sci & Technol, Sch Chem & Mol Engn, Shanghai 200237, Peoples R China;[3]Natl Engn Res Ctr Urban Water Resources, Shanghai 200082, Peoples R China
年份:2019
卷号:11
期号:18
起止页码:2473
外文期刊名:ANALYTICAL METHODS
收录:;EI(收录号:20192006929117);WOS:【SCI-EXPANDED(收录号:WOS:000467878100013)】;
基金:This work was supported by the National Water Pollution Control and Management Technology Major Projects (No. 2017ZX07402003), the Shanghai Municipal Science and Technology Commission (No. 16XD1420500), the Open Project of State Key Laboratory of Urban Water Resource and Environment (No. QA201612), the Shanghai Sailing Program (No. 18YF1406000), the China Postdoctoral Science Foundation (No. 2017M621391) and the Fundamental Research Funds for the Central Universities (No. 222201814055).
语种:英文
外文关键词:Reservoirs (water) - Mass spectrometry - Trace analysis - High performance liquid chromatography - Organic polymers - Potable water - Phase separation - Projectiles - Extraction - Hydrogen bonds
摘要:The solid phase extraction (SPE) method is often used to enrich trace antibiotics in water before analysis by high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS), but the improvement of extraction efficiency has always been the hot issue in this method, which may be realized by developing new SPE materials and optimizing extraction conditions. Tetracyclines (TCs) are a class of common antibiotics, but appropriate SPE materials specifically used to detect them are lacking. Common SPE materials show low and unstable recoveries during the extraction and detection of TCs. In this study, a novel diol-based porous organic polymer (NTdiol-POP) was used as a new SPE material to detect trace TCs in water. This material has specific adsorptive properties for TCs via hydrogen bonds, electrostatic attractive interactions, and p-p interactions. The results show that the NTdiol-POP cartridges have higher recoveries (83.3-118.1%) for determining TCs than common SPE cartridges. Under optimum SPE conditions using NTdiol-POP, TCs were adsorbed at pH 5.0 and eluted with a solution of formic acid/methanol (7%/93%, v/v). Meanwhile, chromatographic separation conditions and MS/MS parameters in multiple reaction monitoring (MRM) mode were optimized to improve the sensitivity and specificity of the instrumental analysis. The limit of detection varied from 0.078 to 2.18 ng L-1, while the limit of quantification varied from 0.26 to 7.25 ng L-1. An assessment of the matrix effects in drinking water exhibited a slight signal variation for most TCs (-8.4% to 2.5%) except oxytetracycline, for which the detection signals were enhanced by 27.0%. The proposed method was successfully applied to determine the trace TCs in three reservoirs of East China.
参考文献:
正在载入数据...