详细信息
Development of micropillar array electrodes for highly sensitive detection of biomarkers ( SCI-EXPANDED收录 EI收录)
文献类型:期刊文献
英文题名:Development of micropillar array electrodes for highly sensitive detection of biomarkers
作者:Chen, Chaozhan[1];Ran, Bin[1];Wang, Zhenxing[2];Zhao, Hongli[2];Lan, Minbo[2];Chen, Huaying[3];Zhu, Yonggang[3]
机构:[1]Harbin Inst Technol, Sch Sci, Shenzhen 518055, Peoples R China;[2]East China Univ Sci & Technol, Shanghai Key Lab Funct Mat Chem, Sch Chem & Mol Engn, Shanghai 200237, Peoples R China;[3]Harbin Inst Technol, Sch Mech Engn & Automat, Shenzhen 518055, Peoples R China
年份:2020
卷号:10
期号:67
起止页码:41110
外文期刊名:RSC ADVANCES
收录:;EI(收录号:20204709516096);WOS:【SCI-EXPANDED(收录号:WOS:000588975500047)】;
基金:This work was supported by the National Natural Science Foundation of China (Grant No. 11772112) and Shenzhen Science and Technology Innovation Committee (Grant No. JCYJ20170413105329648).
语种:英文
外文关键词:Gold coatings - Surface treatment - Yarn - Chemical detection - Diseases - Cyclic voltammetry - Electrochemical electrodes - Geometry
摘要:Micropillar array electrodes (mu AEs) have been widely applied in electrochemical detection owing to their advantages of increased mass transport, lower detection limit, and potential to be miniaturized. This paper reports the fabrication, simulation, surface modification, and characterization of PDMS-based mu AEs coated with gold films. The mu AEs consist of 9 x 10 micropillars with a height of either 100 mu m, 300 mu m, or 500 mu m in a 0.09 cm(2) region. Numerical simulation was employed to study the influence of geometrical parameters on the current density. The mu AEs were fabricated by soft lithography and characterized using both SEM and cyclic voltammetry. Experiments revealed that high pillars enabled enhanced voltammetric current density regardless of the scan rates. The platinum-palladium/multi-walled carbon nanotubes (Pt-Pd/MWCNTs) were coated on the mu AEs to improve their electrochemical detection capability. The mu AEs demonstrated 1.5 times larger sensitivity compared with the planar electrode when hydrogen peroxide was detected. Furthermore, mu AE500 with Pt-Pd/MWCNTs was employed to detect sarcosine, a potential biomarker for prostate cancer. The linear range and limit of detection for sarcosine were from 5 to 60 mu M and 1.28 mu M, respectively. This detection range covers the concentration of sarcosine in human tissues (0-60 mu M). These results suggest that the mu AEs have better detection performance in comparison to planar electrodes due to their large surface area and pillar height. This paper provides essential guidelines for the application of mu AEs in high sensitivity electrochemical detection of low abundance analytes.
参考文献: