Heat Transfer Analysis of Passive Residual Heat Removal Heat Exchanger under Tube outside Boiling Condition  ( SCI-EXPANDED收录 EI收录)  

文献类型:期刊文献

英文题名:Heat Transfer Analysis of Passive Residual Heat Removal Heat Exchanger under Tube outside Boiling Condition

作者:Liu, Yanbin[1];Wang, Xuesheng[1];Men, Qiming[1];Meng, Xiangyu[1];Zhang, Qing[1]

机构:[1]East China Univ Sci & Technol, Sch Mech & Power Engn, Room 637,Bldg 17,130 Meilong Rd, Shanghai 200237, Peoples R China

年份:2017

卷号:2017

外文期刊名:SCIENCE AND TECHNOLOGY OF NUCLEAR INSTALLATIONS

收录:;EI(收录号:20171303493972);WOS:【SCI-EXPANDED(收录号:WOS:000396871900001)】;

语种:英文

外文关键词:Water tanks - Heat transfer

摘要:The Passive Residual Heat Removal Heat Exchanger (PRHR HX) is an important part of the Passive Residual Heat Removal System (PRHRS). The C-shaped bundle is being used in the PRHR HX. A test facility of C-shaped tube immerged in a water tank was built to research the heat transfer of the PRHR HX. Through the experiments, three regions were found within a particular period of time during the heating process in the tank: natural convection region, transition region, and saturation boiling region. For the tube outside saturation boiling, comparisons of three different correlations in literatures with the experimental data were carried out. Results show that the Rohsenow correlation provides a best-estimate fit with the experimental results. For the tube outside transition region, a formulation is put forward to reduce error based on the Rohsenow subcooled boiling correlation.