详细信息

高频脉冲电解法降低香兰素废水COD  ( EI收录)  

Treatment of Vanillin Wastewater by Pulsed High-frequency Electrolysis

文献类型:期刊文献

中文题名:高频脉冲电解法降低香兰素废水COD

英文题名:Treatment of Vanillin Wastewater by Pulsed High-frequency Electrolysis

作者:贺鸣雷[1];张新胜[1];陈银生[1]

机构:[1]华东理工大学联合化学反应工程研究所反应工程国家重点实验室,上海200237

年份:2002

卷号:19

期号:12

起止页码:694

中文期刊名:精细化工

外文期刊名:Fine Chemicals

收录:CSTPCD;;EI(收录号:2003057347023);Scopus;北大核心:【北大核心2000】;CSCD:【CSCD2011_2012】;

语种:中文

中文关键词:高频脉冲电解法;废水处理;香兰素;COD

外文关键词:high-frequency pulse;wastewater treatment;vanillin;COD

摘要:采用先进的高频脉冲电解技术,对香兰素制造过程产生的废水进行了电解处理实验。考察了槽电压、脉冲频率、脉冲占空比、电解时间、pH值以及无机盐质量分数对COD去除率的影响。在槽电压300V,脉冲频率16 1kHz,占空比50%,pH=7 6的条件下,电解1h,COD去除率可达到76 9%。
Wastewater discharging from vanillin factory is treated by electrolysis with highfrequency pulse power supply.Influences of bath voltage,pulse frequency,duty ratio,electrolysis time,pH of wastewater and NaCl concentration of wastewater are investigated.Under the optimal conditions,COD of the wastewater is decreased by 769%.

参考文献:

正在载入数据...