详细信息
Detection of trace metal ions in high-purity boric acid by online two-dimensional valve switching coupled with ion chromatography-inductively coupled plasma mass spectrometry ( SCI-EXPANDED收录)
文献类型:期刊文献
英文题名:Detection of trace metal ions in high-purity boric acid by online two-dimensional valve switching coupled with ion chromatography-inductively coupled plasma mass spectrometry
作者:Wang, Yanping[3];Lou, Sichao[1];Liu, Xin[1];Zhang, Lingfan[1,2]
机构:[1]East China Univ Sci & Technol, Sch Chem & Mol Engn, Shanghai 200237, Peoples R China;[2]East China Univ Sci & Technol, Res Ctr Anal & Test, Shanghai 200237, Peoples R China;[3]Thermo Fisher Sci, Applicat & Prod Ctr, Shanghai 201206, Peoples R China
年份:2020
卷号:155
外文期刊名:MICROCHEMICAL JOURNAL
收录:;WOS:【SCI-EXPANDED(收录号:WOS:000527371500009)】;
基金:We are grateful for the financial support by the National Natural Science Foundation of China (21407050). We also thank the Research Center of Analysis and Test (ECUST) for help on data and characterization, especially thank the engineers X.J Liu and Y.Q Xi for supplying the IC-ICPMS data.
语种:英文
外文关键词:IC-ICPMS; Valve switching; Online detection; Boric acid; Trace metal ions
摘要:In this paper, a two-dimensional valve switching technique was established to detect 10 trace metal ions in high-purity boric acid by ion chromatography-inductively coupled plasma mass spectrometry (IC-ICPMS). The system consisted of a quantitative loop, a matrix capture column, an iminodiacetic acid cationic chelating column, an ion chromatography column, two sample valves and an inductively coupled plasma mass spectrometer. The iminodiacetic acid cationic chelating column coupled the metal ions in the sample with its carboxyl functional groups to separate them from the matrix boric acid solution, and then eluted the chelated metal ions into the ion chromatographic column and inductively coupled plasma mass spectrometer. The proposed method feasibly achieved an online, rapid and efficient detection of 10 trace ions in high-purity boric acid with the optimized experimental conditions (1.0 mol/L HNO3), such as loading solution, loading flow rate, type of eluent, concentration of the eluent, sample matrix, etc. The experimental data showed that this method had good linearity in the range of 0.01-2.0 mu g/L for 10 metal ions, such as Cr, Fe, Ni, Co, V, Mn, Cu, Zn, Cd and Pb in high-purity boric acid samples, with a correlation coefficient greater than 0.998. The limit of detection (LOD, S/N = 3) and the limit of quantitation (LOQ, S/N = 10) were 0.001-0.023 mu g/L and 0.003-0.077 mu g/L, respectively. The relative standard deviation (RSD) of each element was less than 3.0% (n = 6) and the spiked recoveries ranged between 83% and 110%. This method could be proposed to be suitable for determination of trace metal ions in real samples.
参考文献:
正在载入数据...
