详细信息

考虑励磁电流的DAB微逆变器宽负载范围ZVS与无功回流优化混合调制策略  ( EI收录)  

Hybrid Modulation Strategy for Wide Load Range ZVS and Reactive Power Circulation Optimization in DAB Micro-Inverters Considering Excitation Current

文献类型:期刊文献

中文题名:考虑励磁电流的DAB微逆变器宽负载范围ZVS与无功回流优化混合调制策略

英文题名:Hybrid Modulation Strategy for Wide Load Range ZVS and Reactive Power Circulation Optimization in DAB Micro-Inverters Considering Excitation Current

作者:黄文聪[1];蒋煊焱[1];饶天彪[1];常雨芳[1];严怀成[2]

机构:[1]湖北工业大学太阳能高效利用及储能运行控制湖北省重点实验室,武汉430068;[2]华东理工大学信息科学与工程学院,上海200237

年份:2026

卷号:41

期号:8

起止页码:2761

中文期刊名:电工技术学报

外文期刊名:Transactions of China Electrotechnical Society

收录:;EI(收录号:20261820602169);北大核心:【北大核心2023】;

基金:国家自然科学基金资助项目(62473133)。

语种:中文

中文关键词:双有源桥(DAB)微逆变器;模式切换;混合调制;零电压开关;回流功率优化

外文关键词:Dual active bridge micro-inverter;mode switch;hybrid modulation;zero-voltage switching;backflow power optimization

摘要:针对单级式双有源桥(DAB)微逆变器在轻载工况下全开关器件软开关困难与软开关复位电流增加无功回流的问题,该文提出一种基于模式切换的混合调制控制策略。该策略通过变频控制与扩展移相控制相结合,扩展DAB微逆变器的零电压软开关(ZVS)范围的同时优化回流功率。首先,分析DAB微逆变器两种扩展移相调制模式的ZVS特性,通过设计励磁电感扩展了模式切换点处的ZVS范围,提出了ZVS范围内回流功率最小的移相轨迹。然后,设计了变频控制律,该控制律根据轻载和重载条件动态调整开关频率,扩展了轻载时的ZVS范围,降低了重载时的关断损耗。此外,设计了扰动补偿以实现输出电流的精准控制。最后,搭建400 W实验平台,通过实验验证了所提算法性能的优越性。
The dual-active-bridge(DAB)DC-AC converter technology,due to its efficient and flexible power conversion characteristics,has become a key technology for improving energy efficiency and system stability.However,because of the wide output voltage range and considerable output power variation,it is challenging for the DAB DC-AC converter to achieve zero-voltage switching(ZVS)for all switches over a wide output voltage and power range.Additionally,the ZVS condition of the primary lagging switch in the DAB DC-AC converter leads to reactive power during high-frequency power transmission,increasing the conduction loss of the switches.To reduce the impact of these issues on the transmission efficiency of the DAB DC-AC converter,this paper proposes a hybrid modulation control strategy based on mode switching.This strategy combines frequency control with extended phase-shift control to expand the ZVS zone of the DAB micro-inverter while optimizing the circulating power.Firstly,the ZVS characteristics and reactive power characteristics of two extended phase-shift modulation modes of the DAB micro-inverter are analyzed,and a phase-shift trajectory with minimum circulating power within the ZVS zone is proposed.Then,a frequency control law is designed,which increases the switching frequency under light load conditions to expand the ZVS zone and decreases the switching frequency under heavy load conditions to reduce the turn-off loss of the switches.At the same time,A control loop is constructed to achieve precise control of the current.Finally,a 400 W experimental platform is established,and the superiority of the proposed algorithm is verified through experiments.According to experimental results,the proposed control strategy can achieve ZVS for all switches under full load and 20%load conditions.Compared with other phase-shift strategies operating within the ZVS zone under light load conditions,the proposed algorithm reduces the transformer current stress by about 40%and increases efficiency by about 3%.The maximum efficiency of the experimental prototype is 95.69%.The following conclusions are drawn:(1)The proposed phase-shift angle trajectory considers the effects of excitation inductance and the output capacitance of switches.It minimizes reactive power while ensuring ZVS for all switches.(2)The proposed variable-frequency control law increases the switching frequency under light-load conditions,extending the ZVS zone to 20%of the rated power.Under heavy-load conditions,it reduces the switching frequency to minimize turn-off losses.(3)The proposed control loop balances the effects of the filter inductance and the half-bridge capacitance on the output current phase,thereby achieving precise output current control.

参考文献:

正在载入数据...

版权所有©华东理工大学 重庆维普资讯有限公司 渝B2-20050021-7 