详细信息
Modeling and In Vitro Experimental Validation for Kinetics of the Colonoscope in Colonoscopy ( SCI-EXPANDED收录 EI收录)
文献类型:期刊文献
英文题名:Modeling and In Vitro Experimental Validation for Kinetics of the Colonoscope in Colonoscopy
作者:Cheng, Wu-Bin[1,2];Di, Yun-Yun[3];Zhang, Edwin M.[4];Moser, Michael A. J.[5];Kanagaratnam, Sivaruban[5];Korman, Louis Y.[6,7];Sarvazyan, Noune[8];Zhang, Wen-Jun[1,2]
机构:[1]Univ Saskatchewan, Div Biomed Engn, Saskatoon, SK S7N 5A9, Canada;[2]E China Univ Sci & Technol, Complex Syst Lab, Shanghai 200237, Peoples R China;[3]Univ Saskatchewan, Coll Pharm & Nutr, Saskatoon, SK S7N 5C9, Canada;[4]Univ Alberta, Dept Radiol, St Edmonton, AB T6G 2B7, Canada;[5]Univ Saskatchewan, Div Gen Surg, Dept Surg, Saskatoon, SK S7N 0W8, Canada;[6]Chevy Chase Endoscopy Ctr, Chevy Chase, MD 20815 USA;[7]George Washington Univ, Sch Med, Washington, DC 20052 USA;[8]ARTANN Labs Inc, West Trenton, NJ 08618 USA
年份:2013
卷号:41
期号:5
起止页码:1084
外文期刊名:ANNALS OF BIOMEDICAL ENGINEERING
收录:;EI(收录号:20131716244701);WOS:【SCI-EXPANDED(收录号:WOS:000317465000018)】;
基金:The first author wishes to acknowledge financial support received from China Scholarship Council for this research, and give special thanks to Dr. Christina Duriez for his technical support for this research. This research is partially supported by Shanghai Science and Technology Foundation through an international collaborative research funding (Research Funding No.: 12410709900). The authors acknowledge Artann Laboratories for providing CFM device for this research. Development of the CFM was supported by the Grant R44DK068936 from the National Institute Of Diabetes And Digestive And Kidney Diseases.
语种:英文
外文关键词:Colonoscope; Contact force; Frictional force; Kinetics; Porcine colon
摘要:Colonoscopy is the most sensitive and specific means for detection of colon cancers and polyps. To make colonoscopy more effective several problems must be overcome including: pain associated with the procedure, the risk of perforation, and incomplete intubation colonoscopy. Technically, these problems are the result of loop formation during colonoscopy. Although, several solutions such as modifying the stiffness of the colonoscope, using an overtube and developing image-guided instruments have been introduced to resolve the looping problem, the results of these systems are not completely satisfactory. A new paradigm to overcome loop formation is proposed that is doctor-assistive colonoscopy. In this approach, the endoscopists performance is enhanced by providing using a kinetic model that provides information such as the shape of the scope, direction of the colon and forces exerted within certain sections. It is expected that with the help of this model, the endoscopist would be able to adjust the manipulation to avoid loop formation. In the present studies, the kinetic model is developed and validated using an ex vivo colonoscopy test-bed with a comprehensive kinematic and kinetic data collection. The model utilizes an established colon model based on animal tissue with position tracking sensors, contact force sensors for the intraluminal portion of the scope and a Colonoscopy Force Monitor for the external insertion tube.