Monitoring sialylation levels of Fc-fusion protein using size-exclusion chromatography as a process analytical technology tool  ( SCI-EXPANDED收录 EI收录)  

文献类型:期刊文献

英文题名:Monitoring sialylation levels of Fc-fusion protein using size-exclusion chromatography as a process analytical technology tool

作者:Liu, Jintao[1];Chen, Xinning[1,2];Fan, Li[1];Deng, Xiancun[1,2];Poon, H. Fai[2];Tan, Wen-Song[1];Liu, Xuping[1]

机构:[1]E China Univ Sci & Technol, State Key Lab Bioreactor Engn, Shanghai 200237, Peoples R China;[2]Zhejiang Hisun Pharmaceut Hangzhou Co Ltd, Hangzhou 311404, Zhejiang, Peoples R China

年份:2015

卷号:37

期号:7

起止页码:1371

外文期刊名:BIOTECHNOLOGY LETTERS

收录:;EI(收录号:20151200667712);WOS:【SCI-EXPANDED(收录号:WOS:000355685800006)】;

基金:This work was supported by the National Natural Science Foundation of China (Nos. 21106045, 21206040, 21406066), the National High Technology Research and Development Program of China (863 Program) (No. 2012AA02A303), the National Science and Technology Major Project (No. 2013ZX10004003-003-003), the Fundamental Research Funds for the Central Universities (WF1214035).

语种:英文

外文关键词:Cell culture; Critical quality attributes; Critical quality parameters; Fc-fusion protein; Glycosylation; Process analytical technology; SEC-HPLC; Sialic acid

摘要:To develop a rapid process analytical technology (PAT) tool that can measure sialic acid content of an Fc-fusion protein from cell culture samples. A statistical significant correlation between the sialic acid content and size-exclusion chromatography (SEC)-HPLC retention time of an Fc-fusion protein was observed when analyzing the titer of the samples. Using linear fitting analysis, the data fit the model well with R (2) = 0.985. Based on the SDS-PAGE and oligosaccharide analysis, we speculate that the amounts of the glycans could expand the structure of the Fc-fusion protein. This was manifested by the SEC-HPLC method in which proteins were separated based on its molecular size. In order to development a robust PAT method, an internal standard was used to improve the precision of the method by reducing systematic errors. We found the change of SEC retention time (delta t) and sialic acid content were highly correlated (R (2) = 0.992). This method was further validated by a 1500 l production process. SEC-HPLC is a promising PAT tool to monitor the sialic acid content of Fc-fusion protein during biomanufacturing or medium optimization processes.