详细信息

Polycarbonate urethane films modified by heparin to enhance hemocompatibility and endothelialization  ( SCI-EXPANDED收录 EI收录)  

文献类型:期刊文献

英文题名:Polycarbonate urethane films modified by heparin to enhance hemocompatibility and endothelialization

作者:Lu, Yue[2];Shen, Li[3];Gong, Feirong[2];Cui, Jiayang[4];Rao, Ju[2];Chen, Jianding[2];Yang, Wei[1]

机构:[1]Harbin Med Univ, Affiliated Hosp 1, Harbin 150001, Peoples R China;[2]E China Univ Sci & Technol, Sch Mat Sci & Engn, Key Lab Ultrafine Mat, Minist Educ, Shanghai 200237, Peoples R China;[3]Fudan Univ, Zhongshan Hosp, Shanghai Inst Cardiovasc Dis, Shanghai 200032, Peoples R China;[4]Zhejiang Univ Technol, Coll Chem Engn & Mat Sci, Hangzhou, Zhejiang, Peoples R China

年份:2012

卷号:61

期号:9

起止页码:1433

外文期刊名:POLYMER INTERNATIONAL

收录:;EI(收录号:20123315339111);WOS:【SCI-EXPANDED(收录号:WOS:000307310900012)】;

基金:This work was supported by the National Basic Research Program of China (No. 81000105, 30970749 and 30870622) and the National 863 High Technology Research and Development Program of China (2007AA02Z450).

语种:英文

外文关键词:polyurethane; heparin; inflammation; stent

摘要:Polyurethane with pendant carboxyl groups was synthesized by a two-step reaction using methylene diphenyl diisocyanate as hard segments, polycarbonate diols as soft segments and 2,2-bis(hydroxymethyl) propionic acid as chain extenders. The surfaces of the casting polymer films were further covalently conjugated with heparin as confirmed by Fourier transform infrared spectroscopy. The associated surface-exposed heparin content was measured to be 1.92 mu g cm-2 and was shown to be active. Meanwhile, surface hydrophobicity decreased after heparin modification. Heparin immobilization greatly improved the hemocompatibility of polyurethane films both in vitro and in vivo. The in vitro cell responses revealed that the expression of proinflammatory markers CD106 and CD62E of human vein endothelial cells was significantly suppressed on the surfaces of the heparinized polyurethane films, while the affinity and proliferation of the cells were improved. The in vivo performance of this material before and after heparin modification was evaluated as a stent coating material in a porcine coronary artery injury model. Histological analysis indicated that heparinized polyurethane induced mild foreign body reactions and inflammation, which were much lower than those induced by unmodified polyurethane. Heparin immobilization also accelerated the endothelialization process on the surface of the polymer-coated stents when implanted in porcine coronary arteries. More detailed long-term studies are needed to confirm the biostability of the heparin and the endothelialized surfaces. Copyright (c) 2012 Society of Chemical Industry

参考文献:

正在载入数据...

版权所有©华东理工大学 重庆维普资讯有限公司 渝B2-20050021-7 
渝公网安备 50019002500408号 违法和不良信息举报中心