Screening wavelengths with consistent and stable signals to realize calibration model transfer of near infrared spectra  ( SCI-EXPANDED收录 EI收录)  

文献类型:期刊文献

英文题名:Screening wavelengths with consistent and stable signals to realize calibration model transfer of near infrared spectra

作者:Ni, Lijun[1];Han, Mingyue[1];Luan, Shaorong[1];Zhang, Liguo[1]

机构:[1]East China Univ Sci & Technol, Coll Chem & Mol Engn, Shanghai 200237, Peoples R China

年份:2019

卷号:206

起止页码:350

外文期刊名:SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY

收录:;EI(收录号:20183505744633);WOS:【SCI-EXPANDED(收录号:WOS:000447570700045)】;

语种:英文

外文关键词:Near infrared (NIR) spectroscopy; Multivariate calibration transfer; Screening wavelengths with consistent and stable signals; Standard deviation analyzation of spectra

摘要:Measurement environmental changes and spectral signal differences among multi-spectrometers may lead to big error in the process of transferring the model of near infrared (NIR) spectra to secondary instruments. Basing on the common sense, NIR calibration models could be shared directily among multi-instruments, if they were built on the wavelengths at which the spectral signals of secondary instruments are stable and well consistent with the primary's. Present work advanced a method named as screening wavelengths with consistent and stable signals (SWCSS) to transfer NIR calibration models. It eliminates the wavelengths at which the standard deviation of difference spectra between the primary and secondary instruments (SDDSI) is much higher than the standard deviation of precision detection spectra (SDPDS) of a sample tested on the primary and the wavelengths with higher SDPDS values. So that the spectral signals of different instruments at these selected wavelengths are consistent well and stable. The NIR calibration model is built by partial least square regression (PLS) based on the screened wavelengths. Two datasets of corn and radix scutellariae samples measured with different NIR instruments are used to test the performance of the method. The results show that the overall prediction performance of the SWCSS-PLS models for samples measured on secondaries is much better than that of the full wavelength PLS models. The root mean square of error prediction (RMSEP) of the SWCSS-PLS models for samples tested on secondaries is equivalent or superior to that of the piecewise direct standardization (PDS) correction. The SWCSS-PLS model is of fewer parameters, robust and can give good prediction results for samples of secondary instruments. Because standard samples are no longer needed during transferring the calibration models to secondary instruments, SWCSS-PLS models could be directly shared by multi-spectroscopy instruments. (C) 2018 Elsevier B.V. All rights reserved.

参考文献:

正在载入数据...

版权所有©华东理工大学 重庆维普资讯有限公司 渝B2-20050021-7 
渝公网安备 50019002500408号 违法和不良信息举报中心