详细信息

BOD微生物传感器的研究    

Study of a BOD Microbial Sensor

文献类型:期刊文献

中文题名:BOD微生物传感器的研究

英文题名:Study of a BOD Microbial Sensor

作者:储炬[1];李友荣[1]

机构:[1]华东化工学院生化工程研究所

年份:1989

卷号:15

期号:4

起止页码:526

中文期刊名:华东化工学院学报

收录:国家哲学社会科学学术期刊数据库;Scopus;CSCD:【CSCD2011_2012】;

语种:中文

中文关键词:传感器;微生物传感器;制备

外文关键词:sensors; microbial sensor; preparatiou of sensor; properties of sensor

摘要:本文采用夹层法,将异常汉逊酵母固定在氧电极的透氧薄膜与多孔醋酸纤维膜之间,构成一种流通式BOD测试系统。对新研制的电极的各种性能,包括各种理化因子对电极响应的影响作了系统的测试,发现电极电流差值与标准废水的BOD之间存在良好的线性关系,其线性范围为1~45mg/L,电极寿命长达180天以上,响应时间小于20分钟,电极测定重演性好,误差小于6%。
The biochemical oxygen demand (BOD) is one of the most important and widely used parameter in the measurement of organic pollution. The determination of BOD by conventional method takes 5 days, which is too long and complicated for the use in process control. In this paper, a microbial sensor consisting of immobilized yeast cells (Hansenula anomala) and an oxygen electrode was elaborated for the estimation of BOD. The structure of electrode was delicately designed and a flow-through system was set up in this study. The response time of biosensor is within 20 minutes. A linear relationship was observed between the relative current decrease and the BOD of the sample solution (GGA, model waste water) in the range of 1~45 mg/L. The life of the sensor is more than 180 days. The reproducibility of the sensor is quite good, the relative standard deviation is less than 6% at concentration of 20 mg/L BOD. Comparing with other sensors of same type both at home and abroad, many technical specifications of this sensor have been improved.