详细信息

高温裂解/离子色谱法间接检测金属催化剂中的噻吩    

Indirect Determination of Thiophene in Metal Catalysts by Ion Chromatography Coupled with Pyrolysis

文献类型:期刊文献

中文题名:高温裂解/离子色谱法间接检测金属催化剂中的噻吩

英文题名:Indirect Determination of Thiophene in Metal Catalysts by Ion Chromatography Coupled with Pyrolysis

作者:刘鹏宇[1];倪力军[1];张芳芳[2];Solange Muhayimana[3];栾绍嵘[1]

机构:[1]华东理工大学化学与分子工程学院,上海200237;[2]赛默飞世尔科技(中国)有限公司,上海201203;[3]华东理工大学药学院,上海200237

年份:2020

卷号:39

期号:7

起止页码:912

中文期刊名:分析测试学报

外文期刊名:Journal of Instrumental Analysis

收录:CSTPCD;;北大核心:【北大核心2017】;CSCD:【CSCD2019_2020】;

基金:国家自然科学基金项目(21874098,81741095,61775157);山西省重点研发计划(国际科技合作)项目(201903D421053);山西省高等学校科技成果转化培育项目;山西省重点研发计划(高新领域)项目(201903D121158)。

语种:中文

中文关键词:高温裂解;离子色谱;金属催化剂;噻吩;硫酸根

外文关键词:pyrolysis;ion chromatography;metal catalysts;thiophene;sulfate

摘要:建立了高温裂解/离子色谱法间接测定金属催化剂中噻吩含量的分析方法。金属催化剂样品经高温燃烧裂解,使其表面吸附的噻吩转化为SO2和SO3,用含H2O2的碱性吸收液吸收并氧化为SO4^2-,再采用离子色谱法检测吸收液中的SO4^2-浓度,间接计算出金属催化剂中噻吩含量。离子色谱条件为IonPac AS18(4.0 mm×250 mm)阴离子分析柱和IonPac AG18(4.0 mm×50 mm)阴离子保护柱,15 mmol/L氢氧化钾淋洗液,电导检测器检测。结果显示,SO4^2-在2.0~60 mg/L质量浓度范围内线性良好,相关系数为0.9998,SO4^2-的仪器检出限(S/N=3)为1.42μg/L,间接计算得噻吩的检出限和定量下限分别为0.25、1.82μg/g,噻吩的加标回收率为94.7%~97.8%,相对标准偏差(RSD)为1.5%~2.0%。该方法稳定性好、灵敏度高、准确度高,为化工生产过程中噻吩杂质的准确快速检测以及固体样品中有机杂质的检测提供了新思路及新方法。
A novel method was developed for the indirect determination of thiophene in metal catalysts by ion chromatography(IC)with pyrolysis.After combusted in the high temperature oven,the sulfur of thiophene in catalyst was transformed into SO2 and SO3,and then absorbed and oxidized to SO4^2-by absorbing solution containing H2O2.The content of thiophene could be calculated indirectly from the content of SO4^2-in the absorbing solution,which was detected by ion chromatography with suppressed conductivity detector.IonPac AS18(4.0 mm×250 mm)and IonPac AG18(4.0 mm×50 mm)columns were used for elution of the analyte with 15 mmol/L KOH as eluent.In the IC detection,the linear relationship for SO4^2-was excellent in the range of 2.0-60 mg/L with a correlation coefficient of 0.9998.The limit of detection(LOD,S/N=3)for SO4^2-was 1.42μg/L,and the LOD and the limit of quantitation(LOQ)for thiophene in metal catalysts were 0.25μg/g and 1.82μg/g,respectively.The recovery for thiophene ranged from 94.7%to 97.8%,with the relative standard deviation(RSD)of 1.5%-2.0%.The novel method is stable,rapid and sensitive,and it provides a new idea for the analysis of thiophene in the chemical production and some organic impurities in solid samples.

参考文献:

正在载入数据...

版权所有©华东理工大学 重庆维普资讯有限公司 渝B2-20050021-7 
渝公网安备 50019002500408号 违法和不良信息举报中心