Effect of liquid jet diameter on performance of coaxial two-fluid airblast atomizers ( SCI-EXPANDED收录 EI收录)
文献类型:期刊文献
英文题名:Effect of liquid jet diameter on performance of coaxial two-fluid airblast atomizers
作者:Liu, Hai-Feng[1]; Li, Wei-Feng[1]; Gong, Xin[1]; Cao, Xian-Kui[1]; Xu, Jian-Liang[1]; Chen, Xue-Li[1]; Wang, Yi-Fei[1]; Yu, Guang-Suo[1]; Wang, Fu-Chen[1]; Yu, Zun-Hong[1]
机构:[1]E China Univ Sci & Technol, Coll Resource & Environm Engn, Shanghai 200237, Peoples R China
年份:2006
卷号:45
期号:4
起止页码:240
外文期刊名:CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION
收录:;EI(收录号:2005529611371);WOS:【SCI-EXPANDED(收录号:WOS:000234469800001)】;
语种:英文
外文关键词:liquid jet diameter; two-fluid airblast; atomization; coaxial; SMD
摘要:In this paper, the effect of liquid jet diameter on performance of coaxial two-fluid airblast atomizer has been investigated with water-air system in a wide region of liquid/gas mass flux ratio (0.137 < m < 15.6). The Sauter mean diameters (SMD) were measured using Malvern Laser Particle Sizer. The experimental results showed that the liquid jet diameter has striking effect on SMD for large m, but has no effect for small m. For a fixed large m, a decrease of SMD with liquid jet diameter was observed first, followed by an increase. A similar non-monotonic trend was also observed between SMD and liquid jet velocity, We, Re, and M (gas/liquid momentum flux ratio) at the same m, respectively. The minimum SMD is obtained when the velocity of liquid jet flow is about 1.5-4.0 m/s. The following correlation for SMD is developed from the measured data: SMD = 685.8(u(g) - 3.297u(1))(-0.4813)m(0.3665) + 0.1824d(1)m. (c) 2005 Elsevier B.V. All rights reserved.