Determination of trace analytes based on diffuse reflectance spectroscopic techniques: development of a multichannel membrane filtration-enrichment device to improve repeatability  ( SCI-EXPANDED收录 EI收录)  

文献类型:期刊文献

英文题名:Determination of trace analytes based on diffuse reflectance spectroscopic techniques: development of a multichannel membrane filtration-enrichment device to improve repeatability

作者:Li, Wei[1];Wang, Lei[1];Tong, Peijin[1];Iqbal, Jibran[2];Zhang, Xiaofang[1];Wang, Xuan[1];Du, Yiping[1]

机构:[1]E China Univ Sci & Technol, Res Ctr Anal & Test, Shanghai Key Lab Funct Mat Chem, Shanghai 200237, Peoples R China;[2]COMSATS Inst Informat Technol, Interdisciplinary Res Ctr Biomed Mat, Lahore 54000, Pakistan

年份:2014

卷号:4

期号:94

起止页码:52123

外文期刊名:RSC ADVANCES

收录:;EI(收录号:20144400145617);WOS:【SCI-EXPANDED(收录号:WOS:000344389000039)】;

基金:This work was supported by the National Natural Science Foundation of China (21205041) and Science and Technology Commission of Shanghai Municipality (13142201200).

语种:英文

外文关键词:Rhodium compounds - Reflection - Membrane technology - Trace analysis

摘要:The determination of trace analytes based on membrane filtration-enrichment and diffuse reflectance spectroscopic techniques has gained increasing interest in the past decade due to its simplicity, rapidity and high sensitivity. However, poor repeatability primarily attributed to the differences of characteristics between membrane filters limits the development of this technique. In the current study, a simple and effective multichannel device is specially designed for the membrane filtration-enrichment process. The device is able to enrich six samples simultaneously on different positions of a membrane filter and allows the spectroscopic measurement of six samples with only one membrane filter. The proposed approach avoided the effects caused by the nonuniform membrane filters on the performance of the enrichment process. Accuracy and repeatability have been improved significantly for the subsequent on-line spectroscopic detection. A case study was carried out to assess this method utilizing the carcinogenic dye rhodamine B (RhB) as a model analyte. Under the optimal conditions, linearity of the calibration curve based on the Kubelka-Munk function was achieved in the concentration range of 2-30 mu g L-1 with the correlation coefficient (R-2) of 0.9924. Good repeatability was achieved with three average relative standard deviation (RSD) values of 3.6%, 3.8% and 3.8% corresponding to the solutions of 30, 10 and 5 mu g L-1 RhB, respectively. The presented method was successfully employed to quantify RhB in soft drink and river water samples.