流动注射-原子吸收分光光度法测定彩电荧光屏壁玻璃中钾钠钙镁铁    

FIA-AAS DETERMINATION OF K Na Ca Mg AND Fe IN FLUORESCENT SC'REEN GLASS

文献类型:期刊文献

中文题名:流动注射-原子吸收分光光度法测定彩电荧光屏壁玻璃中钾钠钙镁铁

英文题名:FIA-AAS DETERMINATION OF K Na Ca Mg AND Fe IN FLUORESCENT SC'REEN GLASS

作者:章建康[1];周雅丽[1];罗曦云[1];金萍[1]

机构:[1]华东化工学院化学系,上海200237

年份:1994

卷号:30

期号:3

起止页码:16

中文期刊名:理化检验(化学分册)

外文期刊名:Physical Testing and Chemical Analysis(Part B:Chemical Analysis)

收录:北大核心:【北大核心1992】;CSCD:【CSCD_E2011_2012】;

语种:中文

中文关键词:荧光屏;FIA-AAS;玻璃;钾;钠;钙

外文关键词:Fluoresecnt sereen glass Atomie Absorption speetrormetry Flow-injection system

摘要:本文应用流动注射分析-原子吸收分光光度法(FLA-AAS)测定彩电荧光屏壁玻璃中的钾、钠、钙、镁、铁的含量、对方法中可能存在的各种影响因素、干扰情况及其消除等进行了较为详细的研究.应用所建立的方法对样品测定取得了满意结果.
A flow injection system is described for the determination of pouassium.sodium.calcium .magnesium and iron in fluoreseent screen glass by flame aioumic absorption speetrometry. The effects of imerfences on the determination of metals was studied. The detection limits of this method were of the same lcvels as flame atomic absorption spectrometry . and the results agree very well.