详细信息

Simultaneous determination of dihydroxybenzene isomers using disposable screen-printed electrode modified by multiwalled carbon nanotubes and gold nanoparticles  ( SCI-EXPANDED收录 EI收录)  

文献类型:期刊文献

英文题名:Simultaneous determination of dihydroxybenzene isomers using disposable screen-printed electrode modified by multiwalled carbon nanotubes and gold nanoparticles

作者:Li, Da-Wei[1];Li, Yuan-Ting[1];Song, Wei[1];Long, Yi-Tao[1]

机构:[1]E China Univ Sci & Technol, Sch Chem & Mol Engn, Shanghai, Peoples R China

年份:2010

卷号:2

期号:7

起止页码:837

外文期刊名:ANALYTICAL METHODS

收录:;EI(收录号:20103013100302);WOS:【SCI-EXPANDED(收录号:WOS:000280415500009)】;

基金:This work was supported by National High Technology Research and Development Program of China (863 Project No. 2008AA06A406), the Shanghai Postdoctoral Sustentation Fund, China (No. 09R21411700) and the Ministry of Health of China (No. 2009ZX10004-301).

语种:英文

外文关键词:Isomers - Multiwalled carbon nanotubes (MWCN) - Voltammetry - Yarn - Metal nanoparticles - Fiber optic sensors - Electrochemical electrodes - Phenols

摘要:A disposable electrode, modified with multiwalled carbon nanotubes (MWCNTs) and gold nanoparticles (AuNPs), was developed to serve as a sensor for the simultaneous determination of dihydroxybenzene isomers (hydroquinone, catechol and resorcinol). The modified electrode was fabricated by electrodepositing AuNPs on a MWCNTs decorated screen-printed electrode (SPE), then it was characterized in morphology and electrochemical properties and utilized to determine the isomers of dihydroxybenzene in water samples. Compared with bare SPE, AuNPs-modified SPE, and MWCNTs-modified SPE, the fabricated SPE has much stronger electrocatalytic activity for the oxidation of dihydroxybenzenes with the increase of the peak current and the decrease of the potential difference (Delta E-p) between the anodic and cathodic peaks. By using differential pulse voltammetry (DPV), the three isomers can be determined simultaneously and sensitively at the modified SPE. For hydroquinone, catechol and resorcinol, the oxidation peak currents are linear to the concentrations at the range of 2.0 x 10(-6)similar to 7.3 x 10(-4) M, 2.0 x 10(-6)similar to 7.3 x 10(-4) M and 3.0 x 10(-6)similar to 9.6 x 10(-4) M with the detection limits of 3.9 x 10(-7) M, 2.6 x 10(-7) M and 7.2 x 10(-7) M, respectively. Moreover, a rapid on-filed determination is convenient to be performed at this disposable modified SPE incorporated in a portable electrochemical system. These results reveal that the presented sensor can be used for the simultaneous and sensitive on-field determination of dihydroxybenzene isomers.

参考文献:

正在载入数据...

版权所有©华东理工大学 重庆维普资讯有限公司 渝B2-20050021-7 
渝公网安备 50019002500408号 违法和不良信息举报中心