Validation of evaluation model and evaluation indicators comprised Kansei Engineering and eye movement with EEG: an example of medical nursing bed ( SCI-EXPANDED收录 EI收录)
文献类型:期刊文献
英文题名:Validation of evaluation model and evaluation indicators comprised Kansei Engineering and eye movement with EEG: an example of medical nursing bed
作者:Zhou, Zhiyong[1];Cheng, Jianxin[1];Wei, Wheijane[2];Lee, Laichung[3]
机构:[1]East China Univ Sci & Technol, Sch Art Design & Media, Shanghai 200237, Peoples R China;[2]Univ Taipei, Coll Educ, Taipei 008862, Taiwan;[3]Natl Taipei Univ Technol, Coll Design, Taipei 008862, Taiwan
年份:2021
卷号:27
期号:4
起止页码:1317
外文期刊名:MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS
收录:;EI(收录号:20185006237878);WOS:【SCI-EXPANDED(收录号:WOS:000647800200027)】;
语种:英文
外文关键词:Product design - Electrophysiology - Nursing - Eye movements - Eye tracking - Triangulation
摘要:The study is to innovate an evaluation model of medical nursing bed and verify indicators by triangulation of subjective feelings, eye movement and electroencephalography (EEG). The underlying theory is Kansei Engineering that is the technology to measure and transform consumers' perceptions of products into design elements. Kansei Engineering comprises external physiological sensory measurement and intrinsic psychological susceptibility measurement. The evaluation of medical nursing bed should measure subjective and objective data. The current evaluation method of medical nursing bed is very subjective and cannot be tested objectively. It is rationale to apply Kansei Engineering in medical nursing bed evaluation comprised subjective feelings and eye movement with electroencephalography. The methodology is the experimental research in which four design proposals of medical nursing bed were compared by 20 participants. Data collection adopted Tobii X2 eye tracker and NeurOne EEG recording system except subjective feelings. D-lab, ERGOLAB, and EEGLAB was applied to process data of eye movement and EEG. Correlation of triangulation was analyzed for criterion-related validity. Cronbach's Alpha was used as a measure of internal consistency for reliability. Findings indicated design proposal 2 contained a rounded rectangular and line surface organically combined was optimal. Triangulation was supported as indicators for more objective and persuasive evaluation of medical nursing beds. Implications for practice will be applied in NCC Medical Co., LTD, Huashan Hospital Affiliated to Fudan University, Shanghai Ying Hand Medical Equipment Co., Ltd, and WUTRON SAPACE in Shanghai DianJi University. Implications for follow-up research is in proceeding with more participants.