详细信息
Techno-economic analysis and comparison of coal-based chemical technologies with consideration of water resources scarcity ( SCI-EXPANDED收录 EI收录)
文献类型:期刊文献
英文题名:Techno-economic analysis and comparison of coal-based chemical technologies with consideration of water resources scarcity
作者:Zhao, Jinyang[1];Zhou, Li[2];Zhou, Wenji[3];Ren, Hongtao[1];Yu, Yadong[1];Wang, Fuchen[4];Ma, Tieju[1,5]
机构:[1]East China Univ Sci & Technol, Sch Business, Shanghai 200237, Peoples R China;[2]Tsinghua Univ, Inst Energy Environm & Econ, Beijing 100084, Peoples R China;[3]Renmin Univ China, Sch Appl Econ, Beijing 100872, Peoples R China;[4]East China Univ Sci & Technol, Inst Clean Coal Technol, Shanghai 200237, Peoples R China;[5]Int Inst Appl Syst Anal IIASA, Laxenburg, Austria
年份:2021
卷号:38
外文期刊名:ENERGY STRATEGY REVIEWS
收录:;EI(收录号:20214611161048);WOS:【SCI-EXPANDED(收录号:WOS:000741151900004)】;
基金:The authors would like to acknowledge the financial support of the National Natural Science Foundation of China (71874055, 72074077, 71704055, 7196113701, 72131007) .
语种:英文
外文关键词:Energy security; Modern coal chemical industry; Techno-economic analysis; Water constraints; Competitiveness analysis
摘要:Existing techno-economic analyses of modern coal chemical technologies (MCCTs) neglect water constraints, which may underestimate the production cost of MCCTs and thus mislead investment activities. Considering this background, this study incorporated water scarcity and indirect water cost into a classic techno-economic evaluation model of MCCT. Using this model, our work evaluated and compared the techno-economic indicators with the latest data for four typical MCCTs, including coal-to-liquids (CTL), synthetic natural gas (SNG), coal-to-olefin (CTO), and coal-to-ethylene glycol (CTEG). The results demonstrate the following: 1) The production costs of CTL, SNG, CTO, and CTEG are 5185 CNY/t, 2653 CNY/kNm3, 5918 CNY/t, 4055 CNY/t, respectively. Under the current prices of oil-related products, investment in SNG and CTEG would be risky, investment in CTL should be considered cautiously, and investment in CTO could lead to a profit. 2) Under the current market price of water resources, which does not consider the water constraint of MCCTs, the production cost would be underestimated by at most 12.4% for CTL, 10.6% for SNG, 27.5% for CTO, and 32.4% for CTEG. The sensitivity of the results to some key parameters and investment recommendations considering profitability, capital investment, material consumption, water constraints, and CO2 emissions are also discussed and provided.