详细信息

Online fluorescence imaging method by reducing the inequivalent photobleaching for quantitative capillary electrophoresis  ( SCI-EXPANDED收录 EI收录)  

文献类型:期刊文献

英文题名:Online fluorescence imaging method by reducing the inequivalent photobleaching for quantitative capillary electrophoresis

作者:Liu, Chenchen[1,2];Yamaguchi, Yoshinori[1,3];Wang, Yi[1];Dou, Xiaoming[1,3];Kubo, Takuya[2];Otsuka, Koji[2]

机构:[1]East China Univ Sci & Technol ECUST, Sch Sci, Inst Photon & Biomed IPBM, 130 Meilong Rd, Shanghai 200237, Peoples R China;[2]Kyoto Univ, Grad Sch Engn, Dept Mat Chem, Nishikyo Ku, Kyoto 6158510, Japan;[3]Osaka Univ, Grad Sch Sci, Dept Appl Phys, Suita, Osaka 5650871, Japan

年份:2020

卷号:319

外文期刊名:SENSORS AND ACTUATORS B-CHEMICAL

收录:;EI(收录号:20202108701551);WOS:【SCI-EXPANDED(收录号:WOS:000539982800014)】;

基金:This research was partly supported by the National Natural Science Foundation of China [grant number 21804042].

语种:英文

外文关键词:Capillary electrophoresis - Photobleaching

摘要:In traditional capillary electrophoresis (CE) with fluorescence detection, the difference of the migration time of analytes leads to the inequivalent photobleaching, therefore the quantitative determination of the analytes is usually difficult. Especially, when an internal standard (IS) is used, the fluorescent intensities of analytes are hardly comparable to that of the IS if the inequivalent photobleaching is not restricted. We propose a practical approach to reduce the effect of inequivalent photobleaching via an online fluorescence imaging system coupled with the IS method. The detection was operated by the acquisitions of the fluorescent intensities from the divided small section array in the detection window and the electropherograms were obtained from the integrated each acquisition. Compared with the traditional CE detection method, the proposed method demonstrates a real-time detection to collect the fluorescence signals of different analytes under the definite exposure time, rather than the same traversing length. Experimental demonstration for the proposed method was carried out by using DNA-dye conjugations. As a result, our method provided a lower relative error of the peak area ratio of 0.3–3.2 % and a more practical operation because the efforts to restrict the photobleaching are exempted. Revealed in this paper also includes the fact that the photobleaching process manipulated the determination of the peak width and separation resolution. ? 2020

参考文献:

正在载入数据...

版权所有©华东理工大学 重庆维普资讯有限公司 渝B2-20050021-7 
渝公网安备 50019002500408号 违法和不良信息举报中心