详细信息
文献类型:期刊文献
中文题名:制氢转化炉管应力腐蚀失效分析
英文题名:Stress Corrosion Failure Analysis of the HK-40 Tube at Hydrogen Reformer
作者:金杰[1];高增梁[1];张康达[1];柳曾典[2]
机构:[1]浙江工业大学化机所;[2]华东理工大学化机所
年份:1998
卷号:15
期号:2
起止页码:66
中文期刊名:压力容器
外文期刊名:Pressure Vessel Technology
收录:CSTPCD
语种:中文
中文关键词:应力腐蚀;高温炉管;失效分析;制氢转化炉;炼油
摘要:本文通过对制氢炉炉管HK40泄露失效的宏观和微观分析,得出该炉管的失效主要是由H2S和Cl-应力腐蚀造成的,并对防止这类失效提出了建议。
The failure reason of leakage of HK-40 tubes at a hydrogen reformer during long-time high temperature service was analyzed by means of scanning electron microscope and optical microscope. The results show that the failure of the HK-40 tubes was caused by H2S and chlorine ion stress corrosion. Some proposals were given in order to prevent from failure of the heated pipes
参考文献:
正在载入数据...