加氢装置换热器管程排污管的失效分析    

Failure Analysis of Tube-side Draining Duct for Heat Exchanger of Hydrogenation Unit

文献类型:期刊文献

中文题名:加氢装置换热器管程排污管的失效分析

英文题名:Failure Analysis of Tube-side Draining Duct for Heat Exchanger of Hydrogenation Unit

作者:王正东[1];朱奎龙[1];吴东棣[1]

机构:[1]华东理工大学化工机械研究所

年份:2003

卷号:20

期号:4

起止页码:34

中文期刊名:压力容器

外文期刊名:Pressure Vessel Technology

收录:CSTPCD

语种:中文

中文关键词:换热器;排污管;失效;应力腐蚀

外文关键词:heat exchanger; draining duct; failure;stress corrosion

摘要:对某石化厂加氢装置换热器的管程排污管进行了失效分析 ,给出了应力腐蚀开裂并导致排污管失效的影响因素 ,提出了防止该部件失效的改进措施。
A failure analysis of tube-side draining duct was carried out for a heat exchanger of hydrogenation unit in a petrochemical plant. The effective factors for the failure of the draining duct were shown as stress corrosion and cracking. Some improvement suggestions were pointed out to prevent the failure of the component in the future.