Quantitative imaging analysis and investigation of transmission loss in PbF2 crystals by laser ablation-inductively coupled plasma-mass spectrometry method ( SCI-EXPANDED收录 EI收录)
文献类型:期刊文献
英文题名:Quantitative imaging analysis and investigation of transmission loss in PbF2 crystals by laser ablation-inductively coupled plasma-mass spectrometry method
作者:Zhang, Guoxia[1,2,3];Wang, Zheng[3];Li, Qing[3];Zhou, Hui[1,2,3];Zhu, Yan[3];Du, Yiping[1,2]
机构:[1]E China Univ Sci & Technol, Shanghai Key Lab Funct Mat Chem, Shanghai 200237, Peoples R China;[2]E China Univ Sci & Technol, Res Ctr Anal & Test, Shanghai 200237, Peoples R China;[3]Chinese Acad Sci, Shanghai Inst Ceram, 1295 Dingxi Rd, Shanghai 200050, Peoples R China
年份:2016
卷号:154
起止页码:486
外文期刊名:TALANTA
收录:;EI(收录号:20161502242761);WOS:【SCI-EXPANDED(收录号:WOS:000376696400064)】;
基金:The financial support of the Development and Innovation of Instrument Functions, CAS (No. Y27YQ3120G), the Key Program of Creative Funding of SICCAS (No. Y37ZC4140G) and Shanghai technical platform for testing and characterization on inorganic materials (14DZ2292900) are gratefully acknowledged.
语种:英文
外文关键词:Laser ablation-inductively coupled plasma mass spectrometry; PbF2 crystals; Quantitative; Imaging
摘要:We developed a procedure for preparing matrix-matched calibration standards for the quantitative imaging of multiple trace elements in PbF2 crystals by laser ablation -inductively coupled plasma-mass spectrometry (LA-ICP-MS). In this facile approach, PbO powder was employed as the matrix with the addition of a series of standard solutions, followed by drying and tableting, for determining the concentrations ,f Mg-24, Al-27, Y-89, Rh-103, Cs-133, Lu-175 and Bi-209 in transparent samples (with homogeneous element distribution). Pb-206 was chosen as the internal standard and the correlation coefficients of the calibration curves for all elements ranged from 0.9987 to 0.9999 after internal standard correction. The analysis showed good agreement with the results observed by established ICP-MS methods, following acid dissolution of the samples. Finally, the element distributions and transmission curves of a PbF2 sample with non-transparent and transparent sections were visualized. The distribution images, in conjunction with the transmission curves, suggested that the enrichment of Mg, Al, Rh, Cs, and Bi atoms in the non-transparent section of the sample could explain the loss in transmission observed for that section. (C) 2016 Elsevier B.V. All rights reserved.