详细信息

Influence of p-Xylene (PX) accumulation on the operation of pure terephthalic acid (PTA) solvent dehydratic distillation column  ( EI收录)  

文献类型:期刊文献

英文题名:Influence of p-Xylene (PX) accumulation on the operation of pure terephthalic acid (PTA) solvent dehydratic distillation column

作者:Li, Shaojun[1]

机构:[1] Institute of Automation, East China University of Science and Technology, Shanghai 200237, China

年份:2009

卷号:48

期号:13

起止页码:6358

外文期刊名:Industrial and Engineering Chemistry Research

收录:EI(收录号:20093112224634)

语种:英文

外文关键词:Operating costs - Xylene - Dehydration

摘要:In the production of pure terephthalic acid, a tiny amount of reactant p-xylene may enter into the acetic acid dehydration distillation column through the feed stream. In normal operation, p-xylene will not leave the column from the top or bottom product. It will be accumulated in the top of dehydration distillation column and decanter. With the accumulation of p-xylene, the operation cost will be increased gradually, to ensure the purity specifications of the top and bottom products. To reduce the operation cost, it is necessary to cut down the concentration of p-xylene by draining some organic reflux and make up the pure entrainer intermittent. In this paper, reboiler duties at different concentrations of p-xylene in the reflux were analyzed. The optimal operation condition-that the concentration of p-xylene is decreased by draining some organic reflux when the mass fraction of p-xylene accumulation exceeds 0.15-had been suggested. Finally, the residue curves diagram of three key components in the top of the column was used to interpret the draining place of p-xylene. ? 2009 American Chemical Society.

参考文献:

正在载入数据...

版权所有©华东理工大学 重庆维普资讯有限公司 渝B2-20050021-7 
渝公网安备 50019002500408号 违法和不良信息举报中心