详细信息

A novel simple red emitter characterized with AIE plus intramolecular charge transfer effects and its application for thiol-containing amino acids detection  ( SCI-EXPANDED收录 EI收录)  

文献类型:期刊文献

英文题名:A novel simple red emitter characterized with AIE plus intramolecular charge transfer effects and its application for thiol-containing amino acids detection

作者:Huang, Youhong[1,2];Mei, Ju[1,2];Ma, Xiang[1,2]

机构:[1]East China Univ Sci & Technol, Sch Chem & Mol Engn, Key Lab Adv Mat, 130 Meilong Rd, Shanghai 200237, Peoples R China;[2]East China Univ Sci & Technol, Sch Chem & Mol Engn, Inst Fine Chem, 130 Meilong Rd, Shanghai 200237, Peoples R China

年份:2019

卷号:165

起止页码:499

外文期刊名:DYES AND PIGMENTS

收录:;EI(收录号:20191106624879);WOS:【SCI-EXPANDED(收录号:WOS:000463979700064)】;

基金:We thank the financial supports from National Natural Science Foundation of China [grant numbers 21788102, 21875064, 21604023, 21722603 and 21871083), Shanghai Municipal Science and Technology Major Project (Grant No.2018SHZDZX03), Shanghai Sailing Program [grant number 16YF1402200], the Innovation Program of Shanghai Municipal Education Commission, and the Fundamental Research Funds for the Central Universities (222201717003, 222201714011).

语种:英文

外文关键词:AIE; ICT; Red emitter; Fluorescent probe; Thiol-containing amino acids detection

摘要:Developing red fluorescence emitters with simple structures via convenient synthetic routes is highly desirable yet challenging. A novel simple AIE-active red emitter featured with intramolecular charge transfer (ICT) effect was designed by simply integrating common electron donor (D) and acceptors (A) through pi bridges, and facilely synthesized via stepwise asymmetric Knoevenagel condensations. Its AIE property comes out from the non planar 3D configuration and multiple rotors, and the ICT effect is originated from its D A electronic structure. This aldehyde group-functionalized AIEgen holds the capability to specifically detect thiol-containing amino acids in a light-up fashion with notable blue-shift in fluorescence in 2 min. Dramatic difference in the kinetics enabled this probe to differentiate cysteine (Cys) and homocysteine (Hcy) from glutathione (GSH). More interestingly, it generally shows a higher sensitivity to Hcy over Cys. Moreover, the remarkable fluorescence enhancement when the Cys concentration is above 250 mu M and the obvious blue-shift in the UV-Vis absorption spectrum at 15 mu M for Hcy reveal the potential of this AIEgen to be applied as an indicator of Cys/Hcy-related diseases.

参考文献:

正在载入数据...

版权所有©华东理工大学 重庆维普资讯有限公司 渝B2-20050021-7 
渝公网安备 50019002500408号 违法和不良信息举报中心