详细信息

Automatic epileptic EEG classification based on differential entropy and attention model  ( SCI-EXPANDED收录 EI收录)  

文献类型:期刊文献

英文题名:Automatic epileptic EEG classification based on differential entropy and attention model

作者:Zhang, Jian[1];Wei, Zuochen[1];Zou, Junzhong[1];Fu, Hao[1]

机构:[1]East China Univ Sci & Technol, Sch Informat Sci & Engn, Dept Automat, Shanghai 200237, Peoples R China

年份:2020

卷号:96

外文期刊名:ENGINEERING APPLICATIONS OF ARTIFICIAL INTELLIGENCE

收录:;EI(收录号:20204009293132);WOS:【SCI-EXPANDED(收录号:WOS:000582708400025)】;

语种:英文

外文关键词:Electroencephalography; Epilepsy; Differential entropy; Attention mechanism

摘要:In epilepsy electroencephalogram (EEG) analysis, clinicians usually interpret EEG page by page, which is time-consuming and brings heavy workload. This paper proposes a novel automatic epileptic EEG classification approach based on differential entropy and attention mechanism, aiming at designing a short-term epileptic EEG classification model with high accuracy and good generalization performance. Firstly, the original EEG recordings are decomposed into five sub-frequency bands which approximately obey the Gaussian distribution. Afterward, a improved attention model framework considering both row and column attention with a shallower VGGNet (AttVGGNet-RC) is put forward as the classifier. Finally, non-patient specific method is employed to evaluate the performance with pre-tuned hypermeters. With 8-fold data, the proposed model yielded 77.33 +/- 2.91% sensitivity, 86.67 +/- 3.70% specificity and 82.00 +/- 1.43% accuracy, and accuracy was increased by 5.34%, 8.99%, 26.24% and 4.47% respectively compared with multi-layer perceptron (MLP), extreme learning machine (ELM), support vector machine (SVM) and Long Short-Term Memory (LSTM). With 10-fold shuffled data, the improved attention model yielded 93.84 +/- 0.63% sensitivity, 95.84 +/- 0.74% specificity and 95.12 +/- 0.20% accuracy, and the accuracy was 1.34%, 16.29%, 27.12% and 8.24% higher than MLP, ELM, SVM and LSTM respectively. The experimental result showed that the attention model achieved high classification accuracy with low standard deviation as well as good generalization performance. Furthermore, compared with state-of-art epilepsy analysis system, the proposed approach also show better performance. Therefore, this study has significant clinical application value in epilepsy analysis.

参考文献:

正在载入数据...

版权所有©华东理工大学 重庆维普资讯有限公司 渝B2-20050021-7 
渝公网安备 50019002500408号 违法和不良信息举报中心