胶原在聚乳酸旋涂膜表面的吸附研究 ( SCI-EXPANDED收录)
ADSORPTION BEHAVIOR OF COLLAGEN ON THE SPIN-COATED PLA SURFACE
文献类型:期刊文献
中文题名:胶原在聚乳酸旋涂膜表面的吸附研究
英文题名:ADSORPTION BEHAVIOR OF COLLAGEN ON THE SPIN-COATED PLA SURFACE
作者:胡安珍[1];史济斌[1];戎宗明[1];薛平[1];龚飞荣[2];程树军[2]
机构:[1]华东理工大学化学与分子工程学院化学系,上海200237;[2]华东理工大学材料科学与工程学院,上海200237
年份:2010
卷号:20
期号:11
起止页码:1262
中文期刊名:高分子学报
外文期刊名:Acta Polymerica Sinica
收录:CSTPCD;;Scopus;WOS:【SCI-EXPANDED(收录号:WOS:000285074000002)】;北大核心:【北大核心2008】;CSCD:【CSCD2011_2012】;
基金:国家高技术研究发展计划(863计划;项目号2007AA02Z450)资助项目
语种:中文
中文关键词:吸附;石英晶体微天平;胶原;聚乳酸
外文关键词:Adsorption; Quartz crystal microbalance; Collagen; Poly(lactic acid)
摘要:采用石英晶体微天平(QCM)、原子力显微镜(AFM)研究了胶原在聚乳酸旋涂膜表面的吸附,考察了溶液浓度(0~9.25μg/mL)和温度(10~50℃)对胶原吸附的影响.实验结果表明,随着胶原浓度的增加,胶原在聚乳酸表面的吸附量和吸附初速率都相应增加.采用Langmuir模型和Freundlich模型拟合实验数据得到吸附等温线方程,分别为q=11690.99c1+0.99c和q=610c3.179.实验结果显示,Langmuir模型拟合效果要好于Freundlich模型.采用Lagergren拟一阶吸附速率方程和Lagergren拟二阶速率方程拟合不同浓度下的吸附动力学数据.在低浓度下Lagergren拟一阶速率方程拟合效果比较好,在高浓度下Lagergren拟二阶速率方程拟合效果比较好,说明在低浓度时扩散过程是胶原吸附的控速步骤,高浓度时胶原和聚乳酸表面的相互作用是吸附的控速步骤.原子力显微镜显示,吸附在聚乳酸表面的胶原形成网状结构.胶原的吸附受温度影响显著,说明胶原是一种对温度非常敏感的物质.实验结果表明随着温度的升高,在10~40℃范围内胶原的吸附量逐渐降低,在40~45℃范围内锐减,40℃是本实验条件下胶原的变性温度.
The adsorption of collagen on spin-coated poly(lactic acid) (PLA) surface was investigated using quartz crystal microbalance (QCM). The effects of concentration (0 ~ 9. 25 μg /mL) and temperature (10 ~ 50℃ ) on adsorption were studied. The results show that: with the increasing concentration of collagen,the adsorption amount and initial adsorption rate on spin-coated PLA surface increases correspondingly. Langmuir model and Freundlich model were applied for data fitting. The isotherm equations q = 1169 0. 99c1 + 0. 99c and q = 610c 1 3. 79 were obtained. It is found that Langmuir model described experiments better than the Freundlich model. The kinetic experimental data were correlated with the Lagergren pseudo-first order kinetic model and the Lagergren pseudo-second order kinetic model. It is shown that under low concentrations the Lagergren pseudo-first order kinetic model fits the results better and the Lagergren pseudo-second order kinetic fits the results better under high concentrations. It means that the diffusion process is the rate-controlling step under low concentration and the interaction between collagen and PLA surface is the rate-controlling step under high concentrations. The AFM images show that the collagen adsorbed on PLA surface formed mesh-like structure. The adsorption was significantly influenced by temperature changes in the adsorption buffer,indicating that the collagen is a kind of temperature-sensitive material. The results also indicate that collagen denaturalizes gradually with increasing temperature in the range (10 ~ 40℃ ). The adsorption quantity drops sharply when the temperature approaches (40 ~ 45℃ ),40℃ is the denaturizing temperature of collagen under present experimental conditions.