详细信息
竖直多孔管降膜蒸发传热实验 ( EI收录)
Heat transfer experiment of falling-film evaporation in vertical porous tube
文献类型:期刊文献
中文题名:竖直多孔管降膜蒸发传热实验
英文题名:Heat transfer experiment of falling-film evaporation in vertical porous tube
作者:范永坚[1];徐宏[1];徐鹏[1]
机构:[1]华东理工大学机械与动力工程学院,化学工程联合国家重点实验室,上海200237
年份:2016
卷号:67
期号:2
起止页码:512
中文期刊名:化工学报
外文期刊名:CIESC Journal
收录:CSTPCD;;EI(收录号:20161002049544);Scopus;北大核心:【北大核心2014】;CSCD:【CSCD2015_2016】;
语种:中文
中文关键词:烧结型多孔管;降膜蒸发;传热系数;强化传热
外文关键词:sintered porous tube;falling-film evaporation;heat transfer coefficient;heat transfer enhancement
摘要:研究了内表面烧结型多孔管对降膜蒸发换热效果的影响。采用单管降膜蒸发器,由壳程的蒸汽加热管程的水降膜传热。在热通量q=13~90 k W·m^(-2),传热温差ΔT=2.87~9.5℃,液体Reynolds数ReL=4500~15000范围内,求不同工况下管内降膜传热系数,并将其与相对应的光管换热性能进行比较。比较数据可知:多孔管的管内降膜传热系数是光管的2.03倍,总传热系数是光管的1.78倍,多孔管强化传热效果明显。
This paper presents the effect of internal sintered porous tube on the falling-film evaporation heat transfer coefficients.The experiment was performed with a single-tube evaporator,using steam in the shell to heat water in the tube.The falling-film evaporation heat transfer coefficients were calculated under various conditions with heat flux from 13 k W·m^(-2)to 90 k W·m^(-2),heat transfer temperature difference from 2.87℃to 9.5℃,and liquid Reynolds number from 4500 to 15000.The experimental results with a smooth tube are compared to those with an internal sintered porous tube.The results show that the falling-film evaporation heat transfer coefficients of an internal sintered porous tube are 2.03 times that of smooth tube,while the overall heat transfer coefficients are 1.78 times.The enhancement effects for heat transfer of internal sintered porous tube are obvious.