Screening defective lithium ion batteries of 0 V open-circuit voltage by a high current charge process in combination with in situ infrared thermal imaging technology  ( SCI-EXPANDED收录 EI收录)  

文献类型:期刊文献

英文题名:Screening defective lithium ion batteries of 0 V open-circuit voltage by a high current charge process in combination with in situ infrared thermal imaging technology

作者:Duan, Jiyuan[1,2];Wei, Biwen[2];Yang, Rongjing[2];Cai, Chunhao[2];Pan, Jiazhen[1]

机构:[1]E China Univ Sci & Technol, Sch Mech & Power Engn, Shanghai 200237, Peoples R China;[2]Shanghai Entry Exit Inspect & Quarantine Bur, Shanghai 200135, Peoples R China

年份:2012

卷号:16

期号:2

起止页码:597

外文期刊名:JOURNAL OF SOLID STATE ELECTROCHEMISTRY

收录:;EI(收录号:20121314906510);WOS:【SCI-EXPANDED(收录号:WOS:000301040900025)】;

基金:This work is financially supported by Shanghai Entry-exit Inspection & Quarantine Bureau, China.

语种:英文

外文关键词:Lithium ion batteries; Zero open-voltage; Charge; Defective; Infrared thermal imaging; Screening

摘要:How to screen defective lithium ion batteries is of great importance to the producers and consumers, which has been a challenging problem, since some lithium ion batteries will not present evident different electrochemical behaviors at the initial use stage. Here, we found that defective lithium ion batteries of zero open-voltage could be differentiated from the good ones by charging at 1,800 mA (corresponding to 3 C) in combination with in situ infrared thermal imaging technology. During the charge process, the surface temperatures of the defective lithium ion batteries of zero open-voltage showed at least 10 degrees C higher than that of the good one. Results of the charge voltage, charge current, temperature rise, and the analysis of the cathode strip, separator, and anode strip after full-discharge process showed that this method was effective.